Chapter 3 PS-A Monitoring Features
3-3
Error/Alert Notification
Also, when either the one of the above mentioned error/alert occurs, or an external signal input is received, the
following types of alarm processing output signals and features are supported by the PS-A.
Use the included System Monitor feature (utility software) to enable/disable the monitoring features and to set
the alarm processing details.
In addition, you can use the included dynamic link library (API-DLL) to access the RAS features from user-
created applications.
External Output
Signal
General-Purpose Output (DOUT 2-bit)
Various Processing
Functions
LED Indicator (3 colors, 1 lamp)
The three-color LED on the front face is used to indicate the PS-A system
conditions. It is also used as a power ON/OFF indicator.
Pop-up Message Output
This feature displays the system status via a Windows
®
pop-up message.
Buzzer Output
This feature uses the PS-A unit’s built-in speaker to alert the operator
about the system status.
System Shutdown
This feature shuts down the PS-A unit’s OS.
System Reset
This feature resets the system when the Watchdog Timer reaches “time
up”.
SEE
3.3 Monitoring the PS-A Status (page3-11)
SEE
Otasuke Pro! “PS-3650A/PS-3651A Series Reference Manual”
http://www.pro-face.com/otasuke/
SEE
External Input Signals (page3-6)
SEE
LED Indicator (page3-5)