Chapter 2 Specifications
2-25
Pin
No.
RS-485
Signal Name Direction Meaning
1 DATA + Input / Output Send/Receive Data (+)
2 DATA - Input / Output Send/Receive Data (-)
3 NC - No Connection
4 NC - No Connection
5 GND - Signal Ground
6 NC - No Connection
7 NC - No Connection
8 NC - No Connection
9 NC - No Connection
FG FG - Frame Ground (Common with SG)
Be sure to connect pin number 5 (GND) of COM1, COM2 (RS-232C) to the host
unit's Signal Ground terminal.
Be sure to confirm what settings will be used by the other device and set the slide
switches accordingly. Failure to do so can result in a unit malfunction or damage.
Whenever changing the PS-A switches, be sure to first turn the PS-A's power
supply OFF. Failure to do so can cause a PS-A malfunction.
Connect the FG terminal line to the shell.
FG and SG terminals are internally connected in the PS-A. When connecting to
another device, be sure not to create an SG shorting loop in your system.