Chapter 3 Installation and Wiring
3-17
3.2.6 Attach the PS-A unit to an Arm
To attach the PS-A unit to an Arm or to the wall, insert the attachment screws for a commercial-type arm or
wall mount adaptor into the holes in the PS-A’s rear face. (Holes specifications: VESA 75mm) For detailed
attachment instructions, please refer to that product's installation guide. The VESA Arm Attachment Hole
dimensions are signifies as follows;
Arm Attachment Screw Holes (VESA 75mm).
Attach the four (4) M4 attachment screws. (Screw length: 6mm or less.) The torque required for these screws
is 0.7 to 0.8 Nm.
Only for PS-3451A not built-in HDD unit is enabled to use VESA arm or wall
mount adaptor using the VESA arm attachment holes on the rear face.